2016 Fall Meeting

Presentation information

Oral Presentation

III. Fission Energy Engineering » 306-1 Nuclear Safety Engineering, Nuclear Installation Safety, PSA

[1F01-04] Exernal Hazard

Wed. Sep 7, 2016 10:00 AM - 11:00 AM Room F (Kumume City Plaza - Creative Box)

Chair: Koji Morita (Kyushu Univ.)

10:30 AM - 10:45 AM

[1F03] Research and Development of Margin Assessment Methodology of Decay Heat Removal Function against External Hazards

(17)Combination Hazard Curve Evaluation of Forest Fire and Thunder

*Yasushi OKANO1, Hidemasa YAMANO1 (1.Japan Atomic Energy Agency)

Keywords:SFR, External Hazard, Level 1 PRA, Margin evaluation, Forest fire, Thunder, Combinational hazard, Logic tree, Hazard curve

For an evaluation of a combinational hazard of forest fire and thunder, it is necessary to take into account not only the overlap occurrence frequency but also meteorological condition which effects on a forest fire intensity. In this study, the logic tree for a forest fire hazard curve evaluation was utilized to include these effects, and the hazard curve was evaluated for the combinational event of forest fire and thunder.