2017 Fall Meeting

Presentation information

Oral presentation

III. Fission Energy Engineering » 306-1 Nuclear Safety Engineering, Nuclear Installation Safety, PSA

[1B13-16] Evaluation of Source Terms and Radiation Doses 1

Wed. Sep 13, 2017 3:50 PM - 4:55 PM Room B (B12 - B1 Block)

Chair:Masahiko Osaka (JAEA)

4:35 PM - 4:50 PM

[1B16] Development of the evaluation method for the advanced level 2 probabilistic risk assessment

(4)Development of filtered containment venting system performance evaluation tool

*Taizo Kanai1, Masahiro Furuya1, Koichi Nakamura1, Hiroshi Endo1, Yoshihisa Nishi1 (1. CRIEPI)

Keywords:Filtered containment venting system , Level 2 PRA, Source term, Severe accident

A filtered containment venting system (FCVS) reduces containment pressure and the radioactive release into the environment during a severe nuclear power plant accident. The FCVS removes radioactive materials via various process and these performance varies from moment to moment. CRIEPI has developed a FCVS simulator which evaluate aerosol, iodine and organic iodine removal performance by the FCVS (decontamination factor: DF) and the FCVS system behavior.