2017 Fall Meeting

Presentation information

Oral presentation

III. Fission Energy Engineering » 306-1 Nuclear Safety Engineering, Nuclear Installation Safety, PSA

[3C10-12] Seismic PRA 2

Fri. Sep 15, 2017 2:45 PM - 3:35 PM Room C (Open Hall - B1 Block)

Chair:Katsumi Ebisawa (CRIEPI)

3:00 PM - 3:15 PM

[3C11] Investigation and Consideration about Risk Evaluation by Fault Displacements for Nuclear Facilities

Structure Damage on Surface Faulting of 2016 Kumamoto Earthquake

*Masanobu Kamiya1, Masataka Sawada2, Yasuhira Aoyagi2 (1. JAPC, 2. CRIEPI)

Keywords:nuclear safety, fault displacement, suaface faulting, risk evaluation, 2016 Kumamoto Earthquake

Several researchers have investigated about damage of structures on surface faulting of 2016 Kumamoto Earthquake. From their reports, we can understand that a lot of buildings had kept their overall shape even if they had partial damage at their foundations. These findings should also be considered in nuclear safety.