[3I15] Evaluation of cooling capability of isolation condenser under accident conditions

(3) Pressure dependence of cooling capability

*Yasunori Yamamoto1, Masayoshi Mori1 (1. Hokkaido University)

Keywords:isolation condenser, condensation heat transfer, high pressure experiment

Isolation condensers are applied to advanced nuclear power plants as a passive core cooling system. In this study, high pressure experiments simulating isolation condenser were conducted to clarify pressure dependence of condensation heat transfer.