6:15 PM - 6:30 PM
[2J23] Tritium Release Source and Mechanism in Research and Testing Reactors
Keywords:Research and Testing Reactors, primary coolant, tritium, neutron reflector, beryllium, recoil release
An increase of tritium concentration in the primary coolant for JMTR and JRR-3M revealed that the recoil tritium release from the beryllium reflector is dominant.