2019 Fall Meeting

Presentation information

Oral presentation

III. Fission Energy Engineering » 303-1 Reactor Instrumentation, Instrumentation System, Reactor Control / 303-2 Remote Control, Robotics, Image Processing

[3K01-06] Sensing and Data Transmission

Fri. Sep 13, 2019 9:30 AM - 11:05 AM Room K (Common Education Bildg. 2F E21)

Chair:Akio Gofuku(Okayama Univ.)

10:15 AM - 10:30 AM

[3K04] Development of Flow Meter Error Evaluation Technology in Piping System for Nuclear Power Plant

*Takashi Nakahara1, Tatsuro Yashiki1, Junichi Kitamura2, Tadashi Sano1, Yuki Itabayashi1, Takumi Kitagawa2 (1. Hitachi, 2. HGNE)

Keywords:Nuclear Power Plant, Piping System, Flow Meter, Fluid Analysis, Swirl Number

Targeting the piping system of a nuclear power plant, we developed technology to evaluate flow meter error by calculating swing strength change along pipe axis from fluid analysis result, and was able to investigate position where swing is strong and cause why swing is strong.