II. Radiation, Accelerator, Beam and Medical Technologies » 203-5 Medical Reactor and Accelerator, Medical Physics

[2G05-08] Medical Accelerator Technology and RI Production

Thu. Mar 21, 2019 10:50 AM - 12:00 PM Room G (Common Education Bildg. 2 2F No.26)

Chair:Akira Uritani(Nagoya Univ.)

11:05 AM - 11:20 AM

[2G06] 99Mo yields of Mo metal and MoO3 with respect to Ta, W, Pt, and Au converters

*Jaewoong Jang1, Mitsuru Uesaka1 (1. Univ. of Tokyo)

Keywords:Mo-99/Tc-99m, converter, bremsstrahlung, electron linear accelerator, PHITS

Electron linear accelerators utilizing the 100Mo(γ,n)99Mo reaction are a promising alternative to the aging research reactors for 99Mo/99mTc roduction. To investigate the suitable converter for the 100Mo(γ,n)99Mo reaction, we calculated the 99Mo yields of metallic Mo and MoO3 with respect to Ta, W, Pt, and Au converters using PHITS.