3:45 PM - 4:00 PM
[3L14] IC was no operation between earthquake and tunami in F1 No.1 Reactor
Observation of the Simulation of F1- No.1 Reactor by TEPCO
Keywords:isolation condenser, F1 No.1 Reactor, simulation, āccident analysis
The IC operations between earthquake and tsunami on 3.11 are clearly denied by us at the Spring Meeting in 2016. TEPCO researcher made an attempt of MAAP analysis for the certification of IC operation, but the pattern of the figure is not credible.
We showed a numerical confirmation of PRV pressure and condenser heat removal.
We showed a numerical confirmation of PRV pressure and condenser heat removal.