JCI Annual Convention in KOBE

Presentation information

The 40th JCI Technical Conference

B.Structural & Design » Seismic retrofit / Seismic diagnosis / Earthquake damage

Seismic retrofit II / Seismic diagnosis / Earthquake damage

Thu. Jul 5, 2018 1:00 PM - 3:15 PM Room 4 (9F EX3-B)

座長:原田哲夫(土木), 菅野秀人(建築)

[2172] RAPID SEISMIC EVALUATION METHOD OF EXISTING RC BUILDINGS WITH MASONRY INFILL BASED ON EARTHQAUKE DAMAGE

Md Shafiul ISLAM1, Hamood ALWASHALI1, Yuta TORIHATA2, Masaki MAEDA2 (1.Tohoku University 2.東北大学)

Keywords:Existing RC building, Masonry infill, Modified Shiga Map, Seismic Capacity Index

In developing countries, there are enormous stocks of vulnerable masonry infilled RC buildings, which are required to be identified for retrofitting and/or strengthening. This study presents a simple screening procedure, based on the concept of Shiga Map, which considers the cross-sectional areas of RC columns and masonry infills, and their shear strengths as well as corresponding seismic demand. This procedure is further improved by incorporating the effects of secondary factors such as plan irregularities and presence of soft story, which have influences on the seismic behavior.