JCI Annual Convention 2025 in Morioka

Presentation information

The 47th JCI Technical Conference

B. Structural & Design » Shear wall/Earthquake damage

Shear wallⅡ/Earthquake damage

Wed. Jul 16, 2025 3:40 PM - 5:25 PM Room 9 (アイーナ5階 501A)

座長:坂下雅信(建築),須田久美子(土木)

[2102] APPLICATION OF STRENGTHENING TECHNIQUES USING STEEL PIPE REINFORCEMENT TO POST-INSTALLED OPENINGS OF LARGE-SCALE RC SHEAR WALLS AND EXPERIMENTAL VERIFICATION

Margaryta GOLDINA1, Jonathan MONICAL1, Masaki MAEDA1, Naoyuki AIZAWA2 (1.東北大学 2.東北電力)

Keywords:RC、shear wall、post-installed opening、strengthening technique、seismic performance

To limit reductions in seismic performance caused by post-installed openings in reinforced concrete shear walls, conventional strengthening techniques are used to supply additional reinforcing bars around openings. But in cases of nuclear power plants with thick walls, a large amount of concrete is removed which is costly. To compare conventional techniques with less invasive steel pipe reinforcement methods, four specimens with different reinforcement were tested until failure. Compared with the conventional method, walls with steel pipe reinforcement increased stiffness, strength, and ductility.