日本地球惑星科学連合2014年大会

講演情報

口頭発表

セッション記号 A (大気海洋・環境科学) » A-AS 大気科学・気象学・大気環境

[A-AS22_1PM2] 大気化学

2014年5月1日(木) 16:15 〜 18:00 511 (5F)

コンビーナ:*竹川 暢之(東京大学先端科学技術研究センター)、澤 庸介(気象研究所地球化学研究部)、金谷 有剛(独立行政法人海洋研究開発機構地球環境変動領域)、高橋 けんし(京都大学生存圏研究所)、谷本 浩志(国立環境研究所)、座長:竹川 暢之(東京大学先端科学技術研究センター)

16:15 〜 16:30

[AAS22-P08_PG] An Empirical Correction Factor for Filter-based Photo-absorption Black Carbon Measurements

ポスター講演3分口頭発表枠

*IRWIN Martin1KONDO Yutaka1MOTEKI Nobuhiro1 (1.The University of Tokyo)

キーワード:aerosol, black carbon, filter-based measurements, absorption

Long-term observations of black carbon (BC) aerosol provide important information regarding seasonal variations, emission source attribution, and regional distribution & transport. Filter-based BC measurement techniques such as the Continuous Soot Monitoring System (COSMOS) are particularly well suited to this application, due to their relative robustness and reliability. However, caution is required when determining the threshold transmittance, Trthresh (proportional to the time interval between filter changes), in order to ensure that acceptable measurement accuracy is maintained throughout the sampling period. We present a new, empirically derived transmittance-dependent correction factor used to interpret the response characteristics of filter-based aerosol absorption measurements performed by COSMOS. Simultaneous measurements of ambient BC aerosol mass (MBC) were conducted in Tokyo, Japan, using two identical COSMOS instruments operated with different threshold transmittance, Trthresh, values, of 0.95 and 0.6. The derived values for MBC were consistently underestimated by the COSMOS operating at lower Trthresh, as a function of decreasing filter transmittance. The 1-hour averaged values of MBC were underestimated by around 10 %, incorporating measurements across the entire range of filter transmittance (1 - 0.6), with a maximum underestimation at around 17 % immediately preceding filter advancement (i.e. Tr = 〜0.60), and a minimum of 〜1 % immediately following filter advancement (i.e. Tr = 〜1). An empirical second-order correction factor was derived from these ambient measurements, and was applied to MBC as a function of filter transmittance, resolving the instruments to within 2 %.
Furthermore, the operational performance of COSMOS was tested for a new quartz fibre filter (HEPA). A comparison of different filter types demonstrated a systematic overestimation of MBC of around 6 - 8 % when using HEPA filters. A sensitivity study of a radiative transfer model indicated that this enhanced absorption was primarily a result of the increased thickness of the HEPA filter.