日本地球惑星科学連合2015年大会

講演情報

インターナショナルセッション(ポスター発表)

セッション記号 M (領域外・複数領域) » M-IS ジョイント

[M-IS02] Interdisciplinary studies on pre-earthquake processes

2015年5月26日(火) 18:15 〜 19:30 コンベンションホール (2F)

コンビーナ:*服部 克巳(千葉大学大学院理学研究科)、Dimitar Ouzonov(Chapman大学)、劉 正彦(台湾国立中央大学)、黄 清華(北京大学)

18:15 〜 19:30

[MIS02-P04] Visualization of Groundwater Motion Using Self-Potential Tomography for Indoor Rainfall-Induced Landslide Experiment

服部 克巳1、*山崎 智寛1寺嶋 智巳2 (1.千葉大学大学院理学研究科、2.京都大学防災研究所)

As it increases in the frequency of the local heavy rain in recent years, the occurrence number of the landslide also increases. It's an important problem to elucidate the process of the landslide caused by rainfall and monitor the slope and forecast the occurrence time to reduce damages. To achieve this, we need to monitor groundwater movement. In this study, we try to develop the early warning system with SP method to predict/monitor rainfall-induced landslide.
The relationship between the SP fluctuation, the movement of water, and the displacement of soil is confirmed by the former interior flume experiments. We adopt the PRESS-aided Philips-Tikhonov regularization to develop the SP tomography and sandbox experiments to apply the tomography successfully show the water levels and flows. To expand the SP tomography approach to the flume tests, we perform the numerical simulation to visualize the underground water condition. The size of the slope is depth 9.0 m, height 4.8 m and width 1.0 m. And the height of the soil stratum is 0.7 m. We assume a rectangular reconstruction area and we divide the area into a 0.2 m x 0.1 m pixel, and compute the value of electric charge every pixel. In addition we assume the electric charge outside of the slope area is 0 and the permittivity in the analyzed area is uniform. Checkerboard-like positive and negative electric charges are generated and the number of electrodes was changed with 16-85. An error of 10% of the observation value has been added to data observed at electrodes.
We found the following results; (1) it's possible to reconstruct the structure of charge distribution with scale of 1.2 times greater than the inter-electrode distance. (2) the objective selectivity of the optimal reconstructed image with minimum PRESS criterion fails in the case of sparse electrodes.