Japan Geoscience Union Meeting 2015

Presentation information

Oral

Symbol S (Solid Earth Sciences) » S-SS Seismology

[S-SS26] Seismic wave propagation: Theory and Application

Tue. May 26, 2015 11:00 AM - 12:30 PM 103 (1F)

Convener:*Tatsuhiko Saito(National Research Institute for Earth Science and Disaster Prevention), Hisashi Nakahara(Solid Earth Physics Laboratory, Department of Geophysics, Graduate School of Science, Tohoku University), Jun Matsushima(School of Engineering, The University of Tokyo), Kiwamu Nishida(Earthquake Research Institute, University of Tokyo), Kazuya Shiraishi(JGI, Inc.), Chair:Ichiro Kawasaki(Tono Research Institute of Earthquake Science, Association for the Development of Earthquake Prediction), Kazuya Shiraishi(JGI, Inc.)

12:24 PM - 12:27 PM

[SSS26-P15] Application of deconvolution interferometry to extract quality factor of high-rise buildings

3-min talk in an oral session

*Hao WU1, Kazuaki MASAKI2, Kojiro IRIKURA1 (1.Disaster Prevention Research Center, Aichi Institute of Technology, 2.Department of Urban Environment, Aichi Institute of Technology)

Keywords:Deconvolution interferometry, quality factor, microtremor, high-rise buildings

Deconvolution interferometry has been proved an effective method over cross correlation interferometry and coherence interferometry to monitor the health of buildings, extracting the shear velocity and quality factor from earthquake ground motion data or microtremor data (Snieder and Safak, BSSA, Vol. 96 (2), 2006; Nakata et al., BSSA, Vol.103 (3), 2013); Nakata and Snieder, BSSA, Vol. 104(1), 2014). Wang et al. (JAEE, Vol. 13(2), 2013) extended this method to monitor a multi-story damaged building in stricken city with microtremor by extracting the story-by-story shear velocity propagated inside the building during the 2011 Tohoku earthquake. However, the application of this method to estimating the quality factor of the buildings has not been fully investigated.

In this study, we focus on extracting the quality factor of shear waves from deconvolved waves with reference record on the ground floor. We conducted the microtremor measurement simultaneously in five floors for an hour by employing five sets of velocity seismometers with an 800 Hz record logger in several high-rise buildings being over 20 stories. The measurement is accomplished by moving four sets of equipment sequentially with one set fixed at the reference floor. The extracted quality factors of the buildings are expected to provide a reference for damping factor in the analysis of structural response.