日本地球惑星科学連合2015年大会

講演情報

インターナショナルセッション(ポスター発表)

セッション記号 S (固体地球科学) » S-IT 地球内部科学・地球惑星テクトニクス

[S-IT06] Early Earth - from accumulation to formation -

2015年5月25日(月) 18:15 〜 19:30 コンベンションホール (2F)

コンビーナ:*坂巻 竜也(東北大学大学院理学研究科)、鈴木 昭夫(東北大学大学院理学研究科地学専攻)、鎌田 誠司(東北大学大学院理学研究科)、Bjorn Mysen(Geophysical Laboratory, Carnegie Inst. Washington)

18:15 〜 19:30

[SIT06-P06] 超音波法を用いた固体鉄の高温高圧下での弾性波速度測定

*柴崎 裕樹1西田 圭佑2肥後 祐司3五十嵐 愛子4田原 政紀4坂巻 竜也4寺崎 英紀5下山 裕太5桑原 荘馬5田窪 勇作5大谷 栄治4 (1.東北大学学際科学フロンティア研究所、2.東京大学大学院理学研究科、3.高輝度光科学研究センター、4.東北大学大学院理学研究科、5.大阪大学大学院理学研究科)

The Earth's interior has been directly investigated by seismic wave propagation and normal mode oscillation. Based on those observations, the distributions of density and sound velocity of the Earth's interior have been estimated (e.g. PREM). The core, which is located at the center of the Earth, is believed to consist of metallic iron with a certain amount of light elements, such as hydrogen, carbon, oxygen, silicon, and sulfur. A large number of experiments on the compressibility of iron and iron-light element alloys have been carried out in order to constrain the abundances of the light elements in the core. In the past fifteen years, the sound velocities of the iron and iron alloys have also been measured intensively at high pressure. Although the sound velocity consists of longitudinal (VP) and transverse (VS) components, most discussions about the core composition have been based on the only VP data because of the technical issues of the high-pressure experiments. In order to estimate the abundances of the light elements more correctly, the precise measurement of VS as well as VP is necessary. In this study, we measured the VP, VS, and density of solid iron under high-pressure and high-temperature conditions using an ultrasonic method, and X-ray radiography and diffraction techniques.

Simultaneous ultrasonic measurements, and X-ray radiography and diffraction experiments were carried out at BL04B1 beamline, SPring-8 in Japan. High-pressure and high-temperature were generated using a 1500-ton Kawai type multi-anvil apparatus installed at BL04B1 beamline. The experimental conditions were up to 7 GPa and 800 K (stability field of bcc-Fe). The Fe powder or rod was used as the sample. Ultrasonic VP and VS measurements were performed using the pulse reflection method. P- and S-wave signals with a frequency of 57 MHz and 30 MHz, respectively, were generated and received by a 10 degree Y-cut LiNbO3 transducer. The sample was first compressed to the target pressure and heated up to the maximum temperature in each press load in order to reduce the deviatoric stress. Then, we got the ultrasonic data, X-ray radiography image, and X-ray diffractions from the sample and the pressure marker (MgO + hBN) at each about 150-200 K temperature step on decreasing temperature.

Our high-pressure VP and VS data are good agreement with the previous ambient-pressure results measured using the same ultrasonic method [Dever, 1972]. In contrast, our VP data are slightly smaller than the results obtained by high-energy resolution inelastic X-ray scattering (HERIX) technique [Liu et al., 2014]. The values of both VP and VS at high temperature are lower than the linear relationship of a velocity-density, i.e., Birch's law, at room temperature, which is the same trend as the previous HERIX result [Liu et al., 2014].