[AAS13-08] Evaluation of radiative effect on the measurement of the surface air temperature by thermometers using the ground-based microwave radiometer
Keywords:surface meteorological observation, measurement of surface air temperature , thermometer, ground-based microwave radiometer, thermometer screen/shield
Multi-channel ground-based microwave radiometer (MWR) MP-3000A (Radiometrics) measures brightness temperature 14 frequencies in the band of oxygen resonances between 50 and 60 GHz in multiple elevations. The data of strong atmospheric absorption channel (58.8GHz) at minimum elevation angle (9.45 degree) is compared to surface air temperature measured by two thermometers: the platinum resistance thermometer in the artificial ventilated screen (METIC TD-500) and Rotronic S3 temperature and relative humidity sensor in the air-inlet of MWR with an artificial ventilation. The daily boxplot variation of the difference between them is shown in Figure.
Although they display considerable variation, on average variation is small and almost constant in the night time and quite large in daytime with the maximum on around noon. In addition to radiative characteristics of the instruments, the difference of the observation space is possible cause of the difference.
Brightness temperature of the infrared atmospheric radiation indicating a stronger atmospheric absorption should be examined. Comparison with another measurement methods whose radiative effect is small in principle such as very thin resistive wire and ultrasonic anemometer and thermometer is also necessary.
Acknowledgments
The observation at Kagami observation site was supported by the Ministry of Education, Culture, Sports, Science and Technology of Japan under the program of Special Coordination Funds for Promoting Science and Technology, “Japanese Cloud Seeding Experiments for Precipitation Augmentation (JCSEPA)”.
Figure
(a) The boxplot variation of the difference between the air temperature measured by the platinum resistance thermometer in the artificial ventilated screen and the 58.8GHz brightness temperature at elevation angle 9.45 degrees measured by MWR (subtracting the latter from the former) measured in May, 2010 at Kagami observation site, Kochi, Japan. Exclude data with one hour precipitation more than 0.5mm. The line inside the box is the median value. The bottom of the box is the first quartile value and the top of the box is the third quartile. The vertical line from the top of the box extends to the maximum value and the vertical line from the bottom of the box extends to the minimum value. The upper (lower) fence is defined as the third (first) quartile plus (minus) 1.5 times the interquartile range.
(b) Same as (a) but for the difference between the air temperature measured by the platinum resistance thermometer in the artificial ventilated screen and Rotronic S3 temperature and relative humidity sensor in the air-inlet of MWR with an artificial ventilation.
References
International Organization for Standardization, 2007: ISO 17714:2007 Meteorology - Air temperature measurements - Test methods for comparing the performance of thermometer shields/screens and defining important characteristics. 19 pp.
Lacombe, M., D. Bousri, M. Leroy, and M. Mezred, 2011: WMO field intercomparison of thermometer screens/shields and humidity measuring instruments: Ghardaia, Algeria, November 2008-October 2009. World Meteorological Organization, 106 pp.