Japan Geoscience Union Meeting 2016

Presentation information

Poster

Symbol P (Space and Planetary Sciences) » P-CG Complex & General

[P-CG20] Status and perspective of future missions and their instruments and technologies for space sciences

Tue. May 24, 2016 5:15 PM - 6:30 PM Poster Hall (International Exhibition Hall HALL6)

Convener:*Ichiro Yoshikawa(The University of Tokyo), Yoshiya Kasahara(Information Media Center, Kanazawa University)

5:15 PM - 6:30 PM

[PCG20-P01] On relatively shifted centers of the analyzer electrodes of MIA onboard Mercury Magnetospheric Orbiter

*Wataru Miyake1, Shoich Miyazaki1, Yoshifumi Saito2, Shoichiro Yokota2 (1.Tokai University, 2.ISAS/JAXA)

Keywords:MMO, MIA

MIA (Mercury Ion Analyzer) on board MMO employs a top-hat electrostatic analyzer, which measures three dimensional velocity distribution of solar wind and magnetospheric ions around Mercury. The analyzer uses axisymmetric toroidal electrodes and is designed to have no dependence in its characteristics on azimuthal direction of incident ions. However, our ground calibration experiments have revealed that it has a slight dependence. We have tried to explain the dependence by means of model calculations. We assumes that all parts of electrode are manufactured precisely but their centers are not exactly coincident through assembling process. Our result of model calculations suggests that relative shift of 0.1 to 0.2 mm may be included and can be responsible for the azimuthal characteristics of the analyzer.