日本地球惑星科学連合2019年大会

講演情報

[J] ポスター発表

セッション記号 H (地球人間圏科学) » H-SC 社会地球科学・社会都市システム

[H-SC07] 地球温暖化防止と地学(CO2地中貯留・有効利用、地球工学)

2019年5月29日(水) 17:15 〜 18:30 ポスター会場 (幕張メッセ国際展示場 8ホール)

コンビーナ:徂徠 正夫(国立研究開発法人産業技術総合研究所地圏資源環境研究部門)、薛 自求(公益財団法人 地球環境産業技術研究機構)、愛知 正温(東京大学大学院新領域創成科学研究科)

[HSC07-P03] 貯留層中の超臨界CO2影響評価のための繰り返し音波検層における振幅減少情報の利用

*中島 崇裕2,1王 璐琛2,1薛 自求2,1 (1.(公財)地球環境産業技術研究機構、2.二酸化炭素地中貯留技術研究組合)

キーワード:CO2地中貯留、音波検層波形データ、P波速度、P波振幅、長岡サイト

This paper discusses seismic wave attenuation by injected CO2 in the formation. Seismic methods have been broadly used for the monitoring of injected CO2 at many CCS sites. Concerning the velocity change by the existence of CO2, the relationship between P-wave velocity and CO2 saturation in rock samples and formation have been studied well. Some laboratory experiments studied amplitude of P-wave as well as the velocity change by the invasion of CO2, and the change in amplitude was larger than that of time delay (e.g. Muller et al., 2010). Meanwhile investigations on amplitude attenuation were rather limited. In this paper, we investigated P-wave data in the results of time-lapse sonic logging at the Nagaoka site.
At the Nagaoka site, time-lapse well loggings have been conducted during the injection period and post injection period at observation wells, which are 40 m and 60 m apart from the injection well. The sonic logging was conducted 45 times during 12 years using Halliburton’s LFDL (Low Frequency Dipole-Sonic Logging Tool). Since it is not ascertain that the monopole transmitter has emitted the same energy at every logging, we chose a reference point in the cap rock 10 m above the target zone. At this depth, the formation was highly cemented with very small slowness, so the position was easily recognized in wave data and its wave field would not change during the CO2 injection. We took the amplitude of the first P-wave arrival as the reference. We also assume that the emitted energy from the transmitter would not change at the reservoir within 15 m interval from the reference point.
Firstly, we compared the wave data at the depth where the largest change observed by CO2 injected. We can see that the first arrival of P-wave at the nearest observation logging was shifted from 1.64 to 1.8 micro-sec at 14-th run. Amplitude of the peak was also gradually decreased after the CO2 breakthrough, and the amplitude at 21-st run was clearly small. Next we calculated spectrum around the first P-wave arrivals, and found that high frequency components decreased much than the lower frequency components. This frequency shift looked like to be recovered during the imbibition process. These could be an evidence of wave-induced flow of two phase liquid.
From these analyses, amplitude attenuation can be observed in the sonic logging at geological storage site. The combination of seismic wave amplitude and time-delay could be applied for more reliable evaluation of CO2 saturation as Azuma et al. (2014) pointed out. The amplitude change might be effective in the early detection of CO2 leakage along the well, if results as the laboratory experiments were obtained in the field. An effective measurement for this purpose could be realized with the use of DAS-VSP.