11:00 〜 13:00
[ACG43-P05] Development of a portable PM2.5 measurement system for cold regions and its deployment from the Hokuriku region to Northern Japan
キーワード:PM2.5、寒冷地、大気汚染、観測、機器開発、森林火災
We have developed a special insulation box that automatically adjusts the temperature inside to maintain warm even the outside air temperature was severely cold such in the conditions of the winter of Siberia and Alaska, the Arctic, and Antarctica. A portable PM2.5 sensor developed by Nagoya University and Panasonic, Co., Ltd. (Nakayama et al., 2018, https://doi.org/10.1080/02786826.2017.1375078) was installed attached in an iron box and further installed in the insulation box. We confirmed the performance of the insulation box and named the device “the portable PM2.5 measurement system for cold regions” in our recent paper (Yasunari et al., submitted and revised). First, we will summarize the performance of the prototype of the insulation box reported in the paper. After that, some minor updates were carried out for the insulation box, and now its commercial version is available to Tanaka, Co., Ltd. (http://kktanaka.co.jp/products)
To assess the transboundary air pollution transport from the Eurasian continent, such as Siberian wildfire smoke (e.g., Yasunari et al., 2018, https://doi.org/10.1038/s41598-018-24335-w), we recently installed the latest PM2.5 measurement systems in Hakodate (Hokkaido; https://www.arc.hokudai.ac.jp/en/210421-1/), Hirosaki (Aomori; https://www.arc.hokudai.ac.jp/en/210702-1/), and Nagaoka (Niigata; https://www.arc.hokudai.ac.jp/en/211104-1/). We started the observations in 2021 from April 19, June 28, and November 1, respectively. In this presentation, we introduce the time-series data of each observation, comparing them to the nearby station data by the Ministry of Environment from the AEROS website (called Soramame-Kun in Japanese; https://soramame.env.go.jp/). We used the calculated hourly mean data from the measurements at the three sites. We compared them to the nearby AEROS station data (Chubu Elementary School in Hakodate, Bunkyou Elementary School in Hirosaki, and Sirooka-Jihai in Nagaoka). The AEROS station in Hakodate is an ambient air quality monitoring station, and the others in Hirosaki and Nagaoka are roadside monitoring stations. We calculated the number of the most frequently available data per hour for the data periods. On the calculated hourly mean data, we used the mean data for further analyses only when the number of data per hour was greater than 90% of the most frequent value. We used half an hour for plotting, but we also excluded data when the calculated center time of the hour in the hourly mean data by more than one minute due to possible other data biases. On comparisons between our observations and the AEROS data, the highest correlations were found in Hakodate as a case of comparisons with the ambient air quality monitoring station. For example, in Hakodate, on May 8-9, the PM2.5 mass concentrations were highly increased (greater than 50 μg m-3), corresponding to the Asian dust transport from the Gobi desert. In Hirosaki, the AEROS station frequently showed a higher PM2.5 background level. However, our data observed at the rooftop of the Faculty of Science and Technology, Hirosaki University, showed relatively clean background conditions. Although the data covering period is still short in Nagaoka, our data and the AEROS data perhaps capture the large timely variations of PM2.5. However, our data showed a relatively clean PM2.5 background. We introduce more characteristics of the PM2.5 variations on the presentation day at each observation site.
To assess the transboundary air pollution transport from the Eurasian continent, such as Siberian wildfire smoke (e.g., Yasunari et al., 2018, https://doi.org/10.1038/s41598-018-24335-w), we recently installed the latest PM2.5 measurement systems in Hakodate (Hokkaido; https://www.arc.hokudai.ac.jp/en/210421-1/), Hirosaki (Aomori; https://www.arc.hokudai.ac.jp/en/210702-1/), and Nagaoka (Niigata; https://www.arc.hokudai.ac.jp/en/211104-1/). We started the observations in 2021 from April 19, June 28, and November 1, respectively. In this presentation, we introduce the time-series data of each observation, comparing them to the nearby station data by the Ministry of Environment from the AEROS website (called Soramame-Kun in Japanese; https://soramame.env.go.jp/). We used the calculated hourly mean data from the measurements at the three sites. We compared them to the nearby AEROS station data (Chubu Elementary School in Hakodate, Bunkyou Elementary School in Hirosaki, and Sirooka-Jihai in Nagaoka). The AEROS station in Hakodate is an ambient air quality monitoring station, and the others in Hirosaki and Nagaoka are roadside monitoring stations. We calculated the number of the most frequently available data per hour for the data periods. On the calculated hourly mean data, we used the mean data for further analyses only when the number of data per hour was greater than 90% of the most frequent value. We used half an hour for plotting, but we also excluded data when the calculated center time of the hour in the hourly mean data by more than one minute due to possible other data biases. On comparisons between our observations and the AEROS data, the highest correlations were found in Hakodate as a case of comparisons with the ambient air quality monitoring station. For example, in Hakodate, on May 8-9, the PM2.5 mass concentrations were highly increased (greater than 50 μg m-3), corresponding to the Asian dust transport from the Gobi desert. In Hirosaki, the AEROS station frequently showed a higher PM2.5 background level. However, our data observed at the rooftop of the Faculty of Science and Technology, Hirosaki University, showed relatively clean background conditions. Although the data covering period is still short in Nagaoka, our data and the AEROS data perhaps capture the large timely variations of PM2.5. However, our data showed a relatively clean PM2.5 background. We introduce more characteristics of the PM2.5 variations on the presentation day at each observation site.