日本地球惑星科学連合2022年大会

講演情報

[J] ポスター発表

セッション記号 H (地球人間圏科学) » H-SC 社会地球科学・社会都市システム

[H-SC06] 地球温暖化防⽌と地学(CO2地中貯留・有効利⽤、地球⼯学)

2022年6月1日(水) 11:00 〜 13:00 オンラインポスターZoom会場 (15) (Ch.15)

コンビーナ:徂徠 正夫(国立研究開発法人産業技術総合研究所地圏資源環境研究部門)、コンビーナ:薛 自求(公益財団法人 地球環境産業技術研究機構)、愛知 正温(東京大学大学院新領域創成科学研究科)、コンビーナ:今野 義浩(The University of Tokyo, Japan)、座長:薛 自求(公益財団法人 地球環境産業技術研究機構)、今野 義浩(The University of Tokyo, Japan)、愛知 正温(東京大学大学院新領域創成科学研究科)、徂徠 正夫(国立研究開発法人産業技術総合研究所地圏資源環境研究部門)

11:00 〜 13:00

[HSC06-P02] 光ファイバーセンサーを用いた堆積岩コア試料内の流体相変化による変形パターン観察

*朴 赫1薛 自求1 (1.公益財団法人 地球環境産業技術研究機構)

キーワード:光ファイバーセンサー、X線CT、CO2移行、2相流体

If it is known how the deformation pattern of a rock changes as the type of fluid in the rock changes, it can be detected using the difference of deformation pattern when CO2 infiltrates the water-saturated underground. With this in mind, we performed CO2 injection laboratory experiments using core-scale sandstone. Single optical fiber was used as distributed fiber optic sensors in this study. CO2 migration in the specimen was confirmed by X-ray CT images. The purpose of this experiment is to confirm the difference in the reaction of the optical fiber according to the change of the type of fluid in the specimen. Sarukawa sandstone (diameter: 34.8mm, length: 179.5mm) was used in this study. It has a relatively homogeneous structure and has irregularly shaped grains and voids. Microbubble filter (diameter: 34.3mm, length: 5.0mm) was located in between distributor and core specimen in the upstream side. Porosity of the specimen determined by X-ray CT imaging is 23.38%. The permeability is about 5.3mDarcy. The purpose of this experiment is to confirm the difference in the reaction of the optical fiber according to the change of the type of fluid in the sample. The experiment was conducted under the pressure and temperature conditions that simulate underground environments; pore pressure: 10MPa, temperature: 40 degrees Celsius. The confining pressure selected in this study was 12MPa. The specimen was first saturated with KI aqueous solution (11.5 wt%). We continuously checked the reaction of the optical fiber from when the specimen was saturated with KI aqueous solution to during the permeability measurement. Next, supercritical CO2 was injected into the specimen saturated with KI aqueous solution, and CO2 migration was measured using both X-ray CT and optical fiber. In both cases (KIaq only, KIaq+CO2), the differential pressure between the upstream and downstream was 0.5 MPa. ・When one type of fluid (KIaq) flows through the specimen, the optical fiber reaction exhibits a strain gradient in the form of expansion from the upstream side and decreasing degree of expansion toward the downstream side. The shape of the strain gradient was kept constant. ・When two types of fluids (KIaq, CO2) were present, the shape of the strain gradient gradually increased as the CO2 migration progressed. The movement of the deformation front (optical fiber) matched the CO2 migration (X-ray CT). The difference in the expandability of the two fluids may be the cause of the difference in the response of the optical fiber. We concluded that the optical fiber sensor has potential as a tool to detect the migration of CO2 in and around the CO2 storage facility.