11:00 AM - 1:00 PM
[SVC33-P07] Intermittent hydrothermal discharge phenomenon observed at the west crater of Iwo-yama volcano, Kirishima Volcanic Complex, Japan
Keywords:Geysers, Intermittent hydrothermal discharge, Electric self-potential
Then, we performed multi-parameter observations (camera, thermometer, electric self-potential, seismometer, acoustic sensor, tilt meter) for this phenomenon (Fig. 1). The purpose of this study is to clarify the cause of the hydrothermal discharge. In past studies on geyser activity have considered the cause of eruptions follow as: groundwater accumulates in cavities and conduits in the ground, which are heated by geothermal heat to cause boiling (e. g., Mackenzie, 1811; Bunsen, 1847), or the gas that flows into the ground lifts up the water in the conduit (e. g., Kagami, 2016). However, there are few research examples that mention how long before and how groundwater flows in. In this study, new knowledge has been gained in how the movement of water in the ground affects eruption by analysis of self-potential data, which is one of the observation parameter. Next, the particularly important observations obtained in this study are listed.
First, in the temperature data, it was confirmed that the temperature dropped sharply from about 96 [℃] to 70-80 [℃] when the steam discharge stopped, and the temperature rose sharply with the start of hydrothermal discharge. And, at the start of hydrothermal discharge, it shows a low temperature of 80-90 [℃], but 7-14 minutes after, it around 96 [℃], which is the boiling point at the altitude (1233 m) of the west crater. In addition, it was confirmed from the self-potential data that the fluctuation started about 2 hours before the hydrothermal discharge. However, it was also confirmed that self-potential fluctuated but hydrothermal discharge did not occur. In this case, there was a slight decrease in temperature. These self-potential fluctuations may be due to the streaming potential caused by the movement of water in the ground. Furthermore, in the seismic data, it was confirmed that the seismic energy decreased below the 20 Hz band after the self-potential fluctuations, and that the seismic energy increased sharply in the 5-10 Hz band at the same time as the steam discharge stopped. The change in the seismic energy in these low frequency bands may capture the phenomenon inside the conduit.
From these observations, we considered the causes of hydrothermal discharge as follows. First, cold water flows from the conduit wall into the inside of the conduit connected to the lower part of the fumarole at the same time as the start of self-potential fluctuation about 2 hours before the hydrothermal discharge. This weakens the boiling of hydrothermal that originally occurred in the conduit before inflow of cold water. And, the inflow of cold water from the conduit wall increases, a large amount of bubbles containing volcanic gas components supplied from hydrothermal may lift up the inflowing cold water and lead to an eruption. In the future, we aim to elucidate the overall mechanism of the intermittent hydrothermal discharge phenomenon by using infrasound and tilt data.