日本地球惑星科学連合2025年大会

講演情報

[J] ポスター発表

セッション記号 S (固体地球科学) » S-GC 固体地球化学

[S-GC38] 固体地球化学・惑星化学

2025年5月27日(火) 17:15 〜 19:15 ポスター会場 (幕張メッセ国際展示場 7・8ホール)

コンビーナ:下田 玄(産業技術総合研究所地質調査総合センター)、鈴木 勝彦(国立研究開発法人海洋研究開発機構・海底資源センター)、山下 勝行(岡山大学環境生命自然科学学域)、石川 晃(東京工業大学理学院地球惑星科学系)

17:15 〜 19:15

[SGC38-P01] 超苦鉄質岩の主要元素組成分析に関する主要な課題: XRF分析におけるマトリックス効果と火成岩標準物質の標準値再訪

*三國 和音1,2石川 晃1,3佐藤 隆1 (1.東京科学大学地球惑星科学系、2.産業技術総合研究所地質調査総合センター、3.海洋研究開発機構)


キーワード:蛍光エックス線分析、超苦鉄質岩、カンラン岩、マトリックス効果、地球化学標準物質

The dynamics of the Earth's mantle, such as partial melting and deformation, have been directly inferred and unraveled by examining peridotites. Among the various types of information that can be extracted from mantle-derived rocks, whole-rock chemical composition is one of the most fundamental and important information to characterize their origin. Whole-rock major and selected minor elements are routinely quantified through X-ray fluorescence (XRF) analysis, and the quantification of elemental concentrations in igneous samples by XRF is primarily conducted using the calibration curve method with multiple reference materials. While analytical precision and sensitivity largely depend on the instrument, the accuracy of the quantification, which is fundamental to the results, depends on the accuracy of the calibration curve. The accuracy of the calibration curve, in turn, is influenced by the certified values of the utilized reference materials and the matrix effects. Due to the limited availability of ultramafic reference materials with certified major element values (e.g., JP-1), it is necessary to include other igneous rock reference materials in the calibration. Meanwhile, the reference values and the matrix effects have not been thoroughly considered, which could be problematic for the accurate quantification of whole-rock geochemical compositions of peridotites.

Here, we focused on (1) the matrix effect observed in X-ray fluorescence of total iron (T-Fe2O3) of ultramafic rocks compared to other igneous rock matrices and (2) the selection of appropriate reference materials and associated certified values to optimize the major elements, Cr, and Ni analysis for ultramafic rocks by XRF. The issue (1) has not been widely recognized, likely because even if ultramafic rocks exhibit unique matrix effects, the number of ultramafic reference materials included in the calibration curve has been very limited (often only JP-1). As a result, these effects may have either been overlooked as negligible or unintentionally corrected through whole-element matrix collection. Furthermore, regarding issue (2), which has a primary and direct impact on the accuracy of the calibration curve as well, minor elements such as Cr and Ni require careful selection of appropriate values, as multiple data exist for certain reference materials. We use the four certified and an in-house ultramafic reference materials: JP-1, JP-2, OKUM, UB-N, and GP13 to investigate aforementioned issues.