JpGU-AGU Joint Meeting 2017

講演情報

[EE]Eveningポスター発表

セッション記号 P (宇宙惑星科学) » P-PS 惑星科学

[P-PS02] [EE] Small Bodies: Exploration of the Asteroid Belt and the Solar System at Large

2017年5月22日(月) 17:15 〜 18:30 ポスター会場 (国際展示場 7ホール)

[PPS02-P29] In-Situ Landing Analysis of a Jupiter Trojan Asteroid Using a High Resolution Mass Spectrometer in the Solar Power Sail Mission

*癸生川 陽子1伊藤 元雄2青木 順3岡田 達明4,9河井 洋輔3松本 純4寺田 健太郎3豊田 岐聡3薮田 ひかる5圦本 尚義6中村 良介7矢野 創4Cottin Herve 8Grand Noel 8森 治4 (1.横浜国立大学 大学院工学研究院、2.海洋研究開発機構 高知コア研究所 、3.大阪大学大学院理学研究科 、4.宇宙航空研究開発機構宇宙科学研究所 、5.広島大学大学院理学研究科地球惑星システム学専攻 、6.北海道大学理学研究院自然史科学部門 、7.産業技術総合研究所 、8.LISA, Université Paris-Est Créteil, Paris Diderot、9.東京大学)

キーワード:Jupiter Trojan Asteroid, Solar Power Sail , Mass spectrometry

The Solar Power Sail (SPS) mission is one of candidates of the upcoming strategic middle-class space exploration to demonstrate the first outer Solar System journey of Japan. The mission concept includes in-situ analysis of the surface and subsurface (up to 1 m) materials of a Jupiter Trojan asteroid using high resolution mass spectrometry (HRMS). The current mission sequence proposes the launch in late 2020s, and rendezvous to a D or P type Trojan asteroid of ~20-30 km in diameter in 2030s.
The key questions for the Jupiter Trojan asteroid exploration are: (1) constraining planet formation/migration theories, (2) evolution and distribution of volatiles (water and organics) in the Solar System, (3) origin of Earth’s water, and (4) surface processes of Jupiter Trojan asteroids.
We plan to analyze volatile materials on the Jupitar Trojan, for their isotopic and elemental compositions using a HRMS with a combination of pyrolysis ovens and gas chromatography (GC) columns. This HRMS system allows to measure H, N, C, O isotopic compositions and elemental compositions of molecules prepared by various pre-MS procedures including stepwise heating up to 600ºC, pyrolysis-GC, and high-temperature pyrolysis with catalyst in order to decompose the samples into simple gaseous molecules (e.g., H2, CO, and N2). The required mass resolution should be at least 30,000 for analyzing isotopic ratios (e.g., H216O, HD16O and H218O for H and O isotopic measurements) for simple gaseous molecules. For elemental compositions of molecules/ions, mass accuracy of ~10 ppm is required to determine elemental compositions for molecules with m/z up to 300 (as well as compound specific isotopic compositions for smaller molecules). Our planned analytical sequences consist of three runs for both surface and subsurface samples. In addition, ‘sniff mode’ which simply introduces environmental gaseous molecules into a HRMS will be done by the system. The details of the analytical methods and apparatus are under developments.