6:15 PM - 6:30 PM
[14p-D63-19] Evaluation of self-magnetic field of oxide superconducting tapes with ferromagnetic shielding
Keywords:superconductor, ferromagnetic shield
In the case of superconducting tapes, critical current density is largely decreased by magnetic field of c-axial direction. In this research, self-magnetic field of c-axial direction of superconducting tape is reduced by adding ferromagnetic shield, and magnetic field around the superconducting tape is calculated.