5:45 PM - 6:00 PM
▲ [5p-A413-16] High-resolution Point Light Source display
Keywords:3-D display, Point Light Source, Integral Imaging
The problem that occurs when making larger Point Light Source (PLS) display that allows seeing 3-D images without shutter glasses is that it would be massive because of collimating lenses and that makes the distance between two point light sources bigger so the resolution would be low. The point of this research study is to build a thin PLS displays with high-resolution in laboratory condition. The advanced thing is that using 3 × 3 light sources, lens array behind every elemental lens to reduce the distance between point light sources and make the display thinner. We also used a barrier to making emitting angles even. The experimental result of our contrivance shows that reducing the distance of the point of light sources by 3 times makes the resolution 3 times enhanced.