The 78th JSAP Autumn Meeting, 2017

Presentation information

Oral presentation

4 JSAP-OSA Joint Symposia 2017 » 4.8 Strong Light Excitation Phenomena Applied to Materials and Bio Engneering

[8p-A410-1~10] 4.8 Strong Light Excitation Phenomena Applied to Materials and Bio Engneering

Fri. Sep 8, 2017 1:15 PM - 5:00 PM A410 (410)

Masaaki Sakakura(Kyoto Univ.), Koji Hatanaka(Academia Sinica)

2:30 PM - 2:45 PM

[8p-A410-4] The dynamical structural changes in polymers induced by laser irradiation studied by spectrum-tuned 4D X-ray phase tomography based on X-ray Talbot interferometry

〇(P)Karol Vegso1, Hidekazu Takano2, Yanlin Wu2, Masato Hoshino1, Huajie Han3, Yash Sharma4, Atsushi Momose2 (1.JASRI, 2.Tohoku Univ., 3.Univ. Sci. Tech. China, 4.Tech. Univ. Munich)

Keywords:X-ray phase imaging, X-ray Talbot interferometry, polymer, laser ablation

The X-ray Talbot interferometry quantitatively measures phase shift of X-rays in a matter and thus, it is a promising technique to observe soft (low-Z) materials. The X-ray multilayer mirror with bandwidth of 0.1 was installed at beamline BL28B2 at SPring-8 synchrotron radiation facility to reduce radiation damage delivered to the soft-matter specimen. The X-ray Talbot interferometer was constructed downstream of X-ray multilayer mirror at beamline BL28B2 at SPring-8 facility. The polymer specimens of acrylic glass (PMMA) and poly(propyelene) (PP) were illuminated by high-energy infrared laser beam (λ=1064 nm) operating in continuous-wave (CW) mode and propagation of laser-induced pyrolysis in polymer samples was studied by time-resolved X-ray phase imaging. The pilot experiment included fixed sample position and a movie of differential phase images was recorded during laser irradiation with temporal resolution 50 ms. The measurement of movie of differential phase images was continued by 4D X-ray phase CT which provides dynamical change of 3D distribution of real component of index of refraction δ during laser irradiation [1]. The 4D X-ray phase CT using continuous phase stepping method was performed with temporal resolution 4 s. The reconstruction of CT images revealed that defects have character of conically-shaped voids. The growth of burnt area in PP material proceeds from the center of illuminated area to the sample edges (Figs. 1c-d) while in PMMA material, it proceeds from the margin of illuminated area to its center (Figs. 1a-b).