4:00 PM - 6:00 PM
[14p-P5-7] Study on continuous methanol concentration estimation method using shear horizontal surface acoustic wave sensor
Keywords:surface acoustic wave sensor, Estimation method of concentration, Direct methanol fuel cell
Continuous measurements of liquid properties, such as drink and oil, are required. In this paper, a shear horizontal surface acoustic wave (SAW) sensor was installed in a direct methanol fuel cell. Estimation method of concentration of fuel, that is methanol, was discussed. The estimated results were compared with the concentration measured by a conventional density meter. The both value agree well. Therefore, we concluded that the proposed estimation method is the effective for the direct methanol fuel cell.