3:00 PM - 3:15 PM
[12p-B408-7] Development of quantitation method using photon-counting CT and its application to commercial lithium battery.
Keywords:Photon-counting CT, nondestructive measurement, Lithium-ion battery
Photon-counting computed tomography (CT) is a measurement technique to observe CT image which having information of X-ray photon energies. One of the advantages of this technique allows us to quantitatively analyze target material using the X-ray attenuation coefficient. In this study, we present a proof-of-concept study with LiCl aqueous solution and successfully observed CT image of commercial lithium battery using the photon-counting CT. This technique would be expected to opens novel analyzing pathways for nondestructively measure lithium reactions in commercial lithium-ion batteries.