09:30 〜 09:45
[10a-S302-3] デュアルコムファイバーレーザーを用いた非同期サンプリング法によるスピン歳差運動の時間分解測定
キーワード:スピン歳差運動、デュアルコム、非同期サンプリング
In this study, we performed pump-probe experiments using a dual-comb fiber laser source consisting of two ultrashort pulsed fiber lasers with slightly different pulse repetition rates as the pump and probe beams, respectively. The dual-comb light source has equally spaced oscillation frequencies, all of which are stabilized to a reference frequency by a rubidium oscillator. Therefore, a time difference between the pump and probe light is automatically generated in the time domain, and the pump-probe experiment can be realized in a non-mechanical manner. Such a method is called the asynchronous sampling method. In this study, we constructed an optical system using the asynchronous sampling method and realized time-resolved measurement of spin precession.