The 83rd JSAP Autumn Meeting 2022

Presentation information

Oral presentation

CS Code-sharing session » 【CS.6】 Code-sharing Session of 4.5&17

[21a-C302-1~9] CS.6 Code-sharing Session of 4.5&17

Wed. Sep 21, 2022 9:00 AM - 12:30 PM C302 (C302)

Kazunari Matsuda(Kyoto Univ.), Yuhei Miyauchi(Kyoto Univ.)

12:15 PM - 12:30 PM

[21a-C302-9] Zinc oxide on Silicon Wafer / Glass Slide Electrode Deposited via Spray Pyrolysis for Glucose Sensing Application

〇(M2)Melanie Cancino Merciales1,2,3 (1.UP Visayas, 2.DLSU - Manila, 3.UP - Baguio)

Keywords:2D Materials, Oxide electronics, Biosensors

From the electrochemical analyses, the fabricated electrodes (ZnO/Si and ZnO/glass) have the potential for glucose biosensing. It was also found that for higher glucose concentration, 0.5M samples of both ZnO/Si and ZnO/glass have a faster response time. Moreover, all different molarity varied (0.1M, 0.3M, and 0.5M) samples of both ZnO/Si and ZnO/glass exhibited good electrochemical response toward glucose with the current response that ranges from approximately 1mA to 9mA. Furthermore, this study has shown that a low-cost glucose sensor can be fabricated using spray pyrolysis.