[CS12-31] Field demonstration test for bentonite backfill removal in HORONOBE URL- Mechanical removal technique (auger method) -
Keywords:Geological disposal, High-level radioactive waste, Prefabricated Engineered barrier system Module, Retrievability, Mechanical removal technique
Radioactive waste needs to be managed responsibly even after the waste is transported to the final disposal site. Reversibility and retrievability are also required in high level radioactive waste disposal project. From the viewpoint of the technical feasibility of the retrievability, the development of a technology for removing the bentonite backfilling material surrounding the PEM without damaging the PEM is expected. In this paper, we selected the mechanical removal technology using the auger method and verified the feasibility of selected technology in Horonobe URL, depth of 350 meters.