The 57th Annual Meeting of Japanese Society of Pediatric Cardiology and Cardiac Surgery

Presentation information

JCK Session

Session 06(III-JCK06)
Arrhythmia

Sun. Jul 11, 2021 10:40 AM - 12:10 PM Track5 (Web開催会場)

Chair:Jun Yoshimoto(Shizuoka Children’s Hospital, Japan)
Chair:Fen Li(Department of Cardiology/ Heart Center, Shanghai Children’s Medical Center Aliated to Shanghai Jiaotong University School of Medicine, China)
Chair:Myung Chul Hyun(Pediatric Cardiology, Kyung Pook National University Hospital, Korea)

[III-JCK06-1] Efficacy and safety of implantable cardioverter-defibrillator implantation in pediatric with cardiac ion channel diseases

Yiwei Chen, Ji Wei, Zhu Diqi, Li Fen (Department of Cardiology/Heart Center, Shanghai Children’s Medical Center Aliated to Shanghai Jiaotong University School of Medicine, China)

Objective To analyze the indication, efficacy, and complications of implantable cardioverter-defibrillator (ICD) implantation in children with cardiac ion channel diseases. Methods The retrospective study collected the clinical data of 7 patients who accepted ICD implantation in Shanghai Children's Medical Center from January 2009 to January 2021. The etiologies of tachycardia, procedure of the ICD implantation and the operation associated complications were analyzed. Results The 7 patients were aged from 6 years and 5 months to 16 years and 2 months, and their weight were from 15.4 kg to 49.8 kg. Four patients were diagnosed with long QT syndrome, and the remain three were with catecholaminergic polymorphic ventricular tachycardia. All the patients suffered from drug-resistant ventricular tachycardia or ventricular vibration before the operation. After the ICD implantation, 3 patients had electric storm, which were alleviated after analgesics-sedatives treatment with chlorpromazine, dexmedetomidine or midazolam combined with fentanyl, as well as reset of the ICD parameters and support from psychological consultation. The other 4 patients did not undergo any complications as the above comprehensive strategies were given after the operation prophylactically. All patients continued anti-arrhythmic medicine after the operation and all survived at the end of the follow-up period last from 1 month to 7 years. Four patients had ventricular tachycardia (VT) and ventricular vibration, which were successfully recognized and defibrillated by ICD. Conclusions ICD implantation is safe and effective in children and adolescent patients. The electric storm may happen after operation, which could be prevented by the comprehensive strategies including appropriate ICD parameter-setting, analgesics-sedatives treatment and psychological support.