日本地球惑星科学連合2021年大会

講演情報

[J] ポスター発表

セッション記号 M (領域外・複数領域) » M-IS ジョイント

[M-IS25] 大気電気学:極端気象に関連する大気電気現象

2021年6月6日(日) 17:15 〜 18:30 Ch.18

コンビーナ:芳原 容英(電気通信大学 大学院情報理工学研究科)、王 道洪(岐阜大学)

17:15 〜 18:30

[MIS25-P05] Special negative lightning strokes in winter with extremely short preceding discharges

*ウ ティン1、王 道洪1、高木 伸之1 (1.岐阜大学)

キーワード:帰還雷撃、冬季雷、負極性落雷

The return stroke (RS) is the most well-studied process in lightning. The first RS in a negative cloud-to-ground (-CG) flash is usually preceded by the preliminary breakdown (also called initial breakdown) and the stepped leader, and the typical time difference between the start of a -CG flash and the first RS is from several to a few tens of ms. In winter, however, thunderclouds are much shallower and the time difference can be much shorter. -CG flashes with the time difference between the first RS and the start of the flash shorter than 1 ms have been reported. In this study, we will analyze negative strokes in winter with the duration of preceding discharges shorter than 1 ms based on the observation of FALMA (Fast Antenna Lightning Mapping Array). Particularlly, we will focus on strokes with the duration of preceding discharges shorter than 200 us, and we will demonstrate that these strokes are systematically different from those with longer durations of preceding discharges. These special strokes with extremely short preceding discharges frequently occur at high mountain areas. It is estimated that their channel lengths are only hundreds of meters, an order of magnitude shorter than those of normal negative RSs.