Tetsuya Saito1, Makoto Nakano2, Kouichi Okada3, Koji Matsumoto4, Satoshi Gunji5, Katsuyoshi Oyama6, Tsuyoshi Misawa7 (1.Fuel Cycle & Equipment Designing Sec. Nuclear Elctrical, Instrumentation & control Engineering Dept. Nuclear Energy Systems Div. MITSUBISHI HEAVY INDUSTRIES, Ltd., 2. Reactor Core Engineering Dept. Nuclear Energy Systems Div. Energy & Environment, MITSUBISHI HEAVY INDUSTRIES, Ltd., 3.Maintenance Equipment Design Sec. Nuclear Equipment Design Dept. Hitachi-GE Nuclear Energy, Ltd., 4.Nuclear Reactor Engineering Sec. Nuclear Plant Engineering Dept. Hitachi-GE Nuclear Energy, Ltd., 5.Nuclear System Technology R&D Dept. Power & Industrial Systems Reserch & Development Center, TOSHIBA CORPORATION Power Systems Company, 6.NUCLEAR FUEL MANAGEMENT GROUP, NUCLEAR POWER PLANT MANAGEMENT DEPT. TOKYO ELCTRIC POWER COMPANY, 7.Kyoto University Research Reactor Institute)

新たに建設する予定の廃液処理、冷却設備の系統(配管ストレーナやタンク底部)に蓄積する可能性のある燃料デブリによる臨界を防止し、また作業員の速やかな避難活動を促進するために、未臨界状態を監視し臨界近接状態で警報を発する未臨界モニタを開発を進めてきた。
H24年度に中性子検出器の計数率、及びガンマ線検出器によるスペクトロメトリにより監視するシステムの概念設計を実施した。
今年度はシステムの試作検証を実施するべく、京大原子炉研究所の臨界実験所で、基礎データ採取、臨界近接状態におけるシステムの挙動確認、検知アルゴリズム(増倍率法、ノイズ法等)の確認を行い、実機適用に向けた課題を踏まえ、未臨界モニタとしての成立性を評価した。