10:00 AM - 10:15 AM
[1F01] Research and Development of Margin Assessment Methodology of Decay Heat Removal Function against External Hazards
(15)Progress in JFY2015 and Event Sequence Assessment Methodology against a Combination Hazard of Strong Wind and Rainfall
Keywords:Sodium-cooled fast reactor, External hazard, Level 1 PRA , Margin assessment
This study has developed a probabilistic risk assessment and margin assessment methodologies for sodium-cooled fast reactors against representative external hazards. This report describes project overview in JFY2015 and an event sequence evaluation methodology against a combination hazard of strong wind and rainfall.