11:05 AM - 11:20 AM
[3F07] A decontamination characteristic of the metal surface with Uranium hexafluoride
(1) Basic test used simulation sample
Keywords:Uranium hexafluoride, Carbon steel, Corrosion, Decontamination, Water, Diluted acid, Functional electrolyzed water, Hypochlorous acid, Secondary waste
The metal surface exposed to uranium hexafluoride corrodes covering radioactive materials. We studied reasonably decontamination method. In this test, decontamination characteristics using water, diluted acid, functional electrolyzed water were evaluated using a simulated sample. As a result, we found that the oxidation-reduction potential of functional electrolyzed water affects decontamination performance.