11:20 AM - 11:35 AM
[3F08] A decontamination characteristic of the metal surface with Uranium hexafluoride
(2) Basic test used actual sample
Keywords:Uranium hexafle uoride, Carbon steel, Corrosion, Decontamination, Water, Diluted acid, Functional electrolyzed water, Hypochlorous acid, econdary waste
The metal surface exposed to uranium hexafle uoride corrodes covering radioactive materials.
We studied reasonably decontamination method. In this test, decontamination characteristics using functional electrolyzed water were evaluated using a sample.As a result, it was confirmed that the corrosion layer and the base material surface after releasing to the atmosphere that the radioactive substance remained can be effectively removed.
We studied reasonably decontamination method. In this test, decontamination characteristics using functional electrolyzed water were evaluated using a sample.As a result, it was confirmed that the corrosion layer and the base material surface after releasing to the atmosphere that the radioactive substance remained can be effectively removed.