2018年秋の大会

講演情報

一般セッション

III. 核分裂工学 » 304-1 伝熱・流動(エネルギー変換・輸送・貯蔵を含む)

[3I06-10] 福島原発事故2

2018年9月7日(金) 10:45 〜 12:00 I会場 (B棟 B33)

座長:岡本 孝司(東大)

10:45 〜 11:00

[3I06] Assessment of Core Status of TEPCO's Fukushima Daiichi Nuclear Power Plants

(112) Final results of 3 weeks analysis using the SAMPSON code (Unit-3)

*Marco Pellegrini1, Chiaki Kino1, Masao Chaki1 (1. The Institute of Applied Energy)

キーワード:Fukushima Daiichi Nuclear Power Plants, Severe Accident, 3 weeks analysis, SAMPSON

As participant in the project aimed at improving the understanding of Fukushima Daiichi (1F) NPP conditions, IAE has performed a comprehensive evaluation and analyses of the 1F units. At the beginning the accident scenario has been evaluated deeply among all the members of the project, subsequently the SAMPSON code has been applied to confirm assumed phenomena and clarify uncertain points. The analysis has confirmed that at Unit 3 a large portion of the core melted and relocated in the lower plenum. Thereafter, because of lack of cooling, RPV failed and subsequently debris was gradually transferred to the pedestal triggering the MCCI. It is estimated that a little amount of debris might have remained in the lower plenum while a considerable portion relocated to the pedestal with limited spread to the DW.