[2J14] Application of the continuous energy Monte Carlo calculation code MVP-3 to analysis of dynamic parameters of LWR UO2 and MOX critical test cores
Keywords:Light-water-moderation critical experiment, EOLE, TCA, UO2 fuel, MOX fuel, βeff, βeff/l, MVP3, Analysis
Analysis of measured results of βeff and βeff/l was performed using the continuous energy Monte Carlo calculation code MVP-3 for UO2 and MOX cores tested at the light-water-moderation critical facilities EOLE and TCA. The analysis results are reported.