2019 Fall Meeting

Presentation information

Oral presentation

IV. Nuclear Plant Technologies » 403-1 Risk Assessment Technology, Application of Risk Information

[2O10-18] Tsunami PRA

Thu. Sep 12, 2019 2:45 PM - 5:10 PM Room O (Common Education Bildg. 3F A34)

Chair:Katsumi Ebisawa(CRIEPI)

3:15 PM - 3:30 PM

[2O12] Construction of the technical basis for tsunami PRA

Part 3: Fragility Evaluation method of the Watertight Door for the Tsunami Pressure
-Evaluation Method-

*Yoshiaki Watanuki1, Masafumi Matsuyama1, Naoto Kihara1, Hideki Kaida1, Yoshinori Mihara2, Tomonori kitaori3, Atsusi Onouti3 (1. CRIEPI, 2. KAJIMA, 3. Chubu Electric Power)

Keywords:Tsunami PRA, Fragility evaluation, Tsunami pressure, Watertight door

A watertight door is installed in the nuclear power plant for prevention of inundation due to tsunami. We suggested fragility evaluation method about water leakage rate from the door, using the hydraulic test result of watertight doors to consider a realistic response of the watertight door for wave pressure.