2019 Fall Meeting

Presentation information

Oral presentation

IV. Nuclear Plant Technologies » 403-1 Risk Assessment Technology, Application of Risk Information

[2O10-18] Tsunami PRA

Thu. Sep 12, 2019 2:45 PM - 5:10 PM Room O (Common Education Bildg. 3F A34)

Chair:Katsumi Ebisawa(CRIEPI)

3:30 PM - 3:45 PM

[2O13] Construction of the technical basis for tsunami PRA

Part 4: Fragility Evaluation Method of the Watertight Door for the Tsunami Pressure –Application for the Personnel Watertight Door-

*Hideki Kaida1, Masafumi Matsuyama1, Yoshiaki Watanuki1, Naoto Kihara1, Yoshinori Mihara2, Tomonori Kitaori3, Atsushi Onouchi3 (1. Central Research Institute of Electric Power Industry, 2. Kajima Corporation, 3. Chubu Electric Power)

Keywords:Tsunami PRA, Fragility evaluation, Tsunami pressure, Watertight door

In "Construction of the technical basis for tsunami PRA Part 3", we have proposed fragility evaluation method of the watertight door for the tsunami pressure. In this manuscript, applicability of the proposed method for the personnel watertight door is investigated.