10:00 AM - 10:15 AM
[2C01] Calculations of dpa based on new athermal recombination correction model in various radiation enviroments
Keywords:dpa, NRT model, athermal recombination correction (arc), PHITS code
The displacements per atom based on the athermal recombination correction (arc-dpa) is more reliable radiation damage index than the Norgett−Robinson−Torrens model (NRT-dpa). In this study, we calculated the rescaling factor (NRT-dpa/arc-dpa) for neutron irradiations at fission reactor, fusion reactor and accelerator facilities and charged particle irradiations. As a results, we found that this factor ranges from 1.4 to 5.7 for each material and it influences on the evaluation of dpa values.