2021 Fall Meeting

Presentation information

Oral presentation

IV. Nuclear Plant Technologies » 402-1 Nuclear Safety Engineering (Safety Design, Safety Assessment/Analysis, Management)

[1E07-11] Severe Accident1

Wed. Sep 8, 2021 2:45 PM - 4:10 PM Room E

chair: Takahiro Arai (CRIEPI)

3:45 PM - 4:00 PM

[1E11] Development of Passive Debris Cooling System Phase II

(7)Applicability Evaluation

*Mika Tahara1, Satoru Kuboya1, Yuya Takahashi1, Shohei Kanamura1, Keisuke Tsukada1, Yasushi Yamamoto1, Hideki Horie1, Yoichi Onitsuka1, Tadashi Fujii2, Takumi Yoshikawa3 (1. TOSHIBA ESS, 2. HGNE, 3. JAPC)

Keywords:MCCI, Fire refractory material

Heat transfer and erosion evaluation of the fire refractory material in actual plant conditions were carried out, and the fire refractory material laminated structure which controls MCCI was examined. In HP-ABWR, even if water supply is performed after debris fall, MCCI can be prevented by lamination of ZrO2 and Al2O3 fire refractory material. On the other hand, in Mark-II, in order to mitigate MCCI, it is desirable to use together with measures, such as particle formation by the debris fall into water, with installation of a fire refractory material.