3:45 PM - 4:00 PM
[1H10] Replacement of the laboratory detritiation system and its performance test
Keywords:detritiation system, oxidation catalyst, molecular sieve
The laboratory detritiation system was replaced to new detritiation system. The catalytic oxidation and water adsorption method was applied for the detritiation process in new laboratory detritiation system. The detritiation process is same as the former one. In design of new detritiation system, we changed the piping material, control board and so on. In the presentation, the requirement of new system will be described. And the results of the performance test of the new detritiation system can be applicable to practical situations.