2022 Fall Meeting

Presentation information

Oral presentation

V. Nuclear Fuel Cycle and Nuclear Materials » 505-3 Decommissioning Technology of Nuclear Facilities

[2B06-09] Decommissioning of Fukushima Daiichi NPP 2

Thu. Sep 8, 2022 10:50 AM - 11:55 AM Room B (E1 Bildg.2F No.21)

Chair:Taro Shimada(JAEA)

11:05 AM - 11:20 AM

[2B07] Development of ultramicro analysis technology for fuel debris analysis

(15)Mutual Discrimination of Am/Cm using ICP-MS/MS

*Hiroyuki Kazama1, Yoshihiro Sekio1, Koji Maeda1, Shinichi Koyama1, Tatsuya Suzuki2, Kenji Konashi3, Chikage Abe3, Yasuyoshi Nagai3 (1. JAEA, 2. Nagaoka Univ. of Tech., 3. Tohoku Univ.)

Keywords:Fuel debris, ICP-MS/MS, Am, Cm, Analytical chemistry

Triple-quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) is attractive technique to perform rapid and accurate analysis of fuel debris in Fukushima Daiichi Nuclear Power Plant. The collision/reaction cell technology incorporated in ICP-MS/MS is an available option to eliminate isobaric interferences, being expected to simplify the pretreatment of fuel debris analysis. When fuel debris contains Am and Cm, the pretreatment involving Am/Cm separation is difficult due to similarly chemical behavior of these actinides. In this study, ICP-MS/MS measurements of 241Am and 244Cm injecting CO2 were carried out. From the obtained results, we suggest candidate conditions to discriminate the isobars of these actinides by use of the differences in their molecular ion formation tendency with variation of CO2 flow rate.