[3C11] Present status of Linear IFMIF Prototype Accelerator (LIPAc)

(3)Misalignment evaluation of medium energy beam transport line with beam-based alignment

*Jibong Hyun1, Hiroki Usami1, Kai Masuda1, Keitaro Kondo1, Akihiko Mizuno1,2, Manuel Peres Alonso3, Francesco Scantamburlo4 (1. QST, 2. JASRI, 3. IPFN, 4. F4E)

Keywords:Proton/Deuteron accelerator, Beam based alignment, RFQ, quadrupole magnet

The LIPAc consists of an injector, an RFQ, MEBT, a diagnostic plate, HEBT, and a beam dump. Each component was aligned within an accuracy of +/-0.2 mm in the beamline, however, a misalignment of about 0.5 mm in the horizontal direction between the RFQ and the 1st quadruple magnet of MEBT was recently measured by the alignment survey with a laser tracker. We carried out the beam-based alignment for MEBT components and evaluated misalignments for each component. In this meeting, the results of comparisons between laser-based alignment and beam-based alignment will be reported.