2023 Fall Meeting

Presentation information

Oral presentation

IV. Nuclear Plant Technologies » 403-1 Risk Assessment Technology, Application of Risk Information

[2N06-09] Seismic PRA 2

Thu. Sep 7, 2023 10:55 AM - 12:00 PM Room N (School of Eng. Bildg. 2F 521)

Chair:Hitoshi MUTA(TCU)

11:25 AM - 11:40 AM

[2N08] Study on the improved fragility evaluation method of electrical raceways (1) Outline of study plan

*Tomokazu Higuchi1, Tatsuya Oku1, Tomoyuki Fukuoka1, Naotomo Maruyama2, Shinji Kosugi3, Ryusuke Haraguchi4, Masatsugu Bando5, Ryuta Shimosakoda6, Shinichi Hisatomi6, Ryotaro Tatsuzawa6 (1. TOSHIBA ESS, 2. HGNE, 3. Hitachi, 4. MHI, 5. MHI NS Engineering, 6. TEPCO HD)

Keywords:Electrical raceway, Cable, Cable tray, Examination, Capacity, Fragility

In fragility evaluation of cable tray among electrical raceways, it is supposed that damage of cable tray body or its support structure led to cable damage and loss of electric function. But it is possible to think that damage of cable tray body or its support structure does not lead to cable damage and loss of electric function. If the capacity of electric function of cable is stronger than strength capacity of cable tray body or its support structure, it is thought that fragility of cable tray is improved. Therefore, examination for confirming capacity of electric function of cable was planned. Already, cable specification used in nuclear power plant was investigated, and load acted on cable was confirmed by analysis.