3:45 PM - 4:00 PM
[3F14] Development of the radiation resistant remote vibration sensing device for the reactor decommissioning
Keywords:Decommissioning, Damage Evaluation, Vibration Measurement, Radiation resistance, Concrete, Degraded area detection
In response to the previous remarks received about the remote microvibrometer for evaluating the integrity of damaged structures, etc., we continuously irradiated the microvibrometer in operation with gamma rays and confirmed that it did not cause any problem in its operation. In addition, sound velocity measurements of concrete specimens containing elements damaged by heating were obtained, indicating the possibility of detecting damaged portions.