2024 Annual Meeting

Presentation information

Oral presentation

IV. Nuclear Plant Technologies » 402-1 Nuclear Safety Engineering (Safety Design, Safety Assessment/Analysis, Management)

[3D01-05] Containment Filtered Venting System

Thu. Mar 28, 2024 9:45 AM - 11:05 AM Room D (21Bildg.3F 21-312)

Chair:Hidetoshi Karasawa(JAEA)

9:45 AM - 10:00 AM

[3D01] Development of Advanced Filtered Containment System

(1) Development Plan

*Tadashi Narabayashi1, Hiroshige Kikura1, Koji Endo2, Tomohiko Yoshii3, Sanshiro Kobayashi4 (1. Tokyo Institute of Technology, 2. Rasa Industry, 3. KCPC, 4. Morimura Bros.)

Keywords:Filtered Contaiment Venting System, Decontamination Factor

In order to develop the advanced filtered Containment Venting System (FCVS), we developed a low pressure drop scrubber nozzle, improved the decontamination coefficient by preventing waves in the scrubber pool, developed a safety relief valve to automatically start the FCVS, optimized the multilayer metal fiber system, and developed silver zeolite. Efforts were made to improve the decontamination coefficient by selectively using AgX and AgR, and to install xenon adsorption filters.