[P-ITu-08] Full-Color High-Speed Computer-Generated Holography with Digital Micromirror Device
[Presentation Style] Onsite
In this study, we investigated the full-color high-speed reproduction of CGH using a digital micromirror device (DMD). In the experiment, we used a DMD as a display device for CGH and obtained full-color hologram images using a time-divided method. Since the reproduced images were relatively close to the original 3D model with high speed, we believe that we could demonstrate the effectiveness of DMD as a display device for CGH to reproduce 3D images in full color.