JCI Annual Convention in TAKAMATSU

Presentation information

Material & Construction » Fire resistance

Fire resistance Ⅱ

Thu. Jul 10, 2014 10:45 AM - 12:15 PM 第5会場 (61会議室)

[1222] TEMPERATURE DISTRIBUTION IN CRACKED MORTAR PRISM IN FIRE CONDITION

Mohammad Mahdi RAOUF FARD1, Atsuko TOMINAGA2, Masanobu SAKASHITA2, Minehiro NISHIYAMA2 (1.Kyoto University 2.京都大学)

Keywords:crack, elevated temperatures, fire test, mortar, reinforced concrete, temperature distribution, FEM analysis, 鉄筋コンクリート, モルタル, 高温度, ひび割れ, 耐火実験, 温度分布, FEM解析

論文PDFを表示
*大会会期中のみ閲覧可能です。
A series of fire tests on reinforced concrete (RC) members have been conducted to study the structural response of different parts exposed to elevated temperatures. However, the effect of crack had not been investigated fully yet. Since cracks make the entire RC structure susceptible to fire, the present paper studies effect of cracks on internal temperature distributions by conducting a series of fire tests on mortar prism specimens along with FEM analyses. The cracked zone tended to attain higher internal temperatures than its adjacent intact zones.